head_writing logo






deutsche version
franzözischeversion
spanische version
russische version
chinesische version

Additional devices -

Immersion coolers, Through-flow coolers, Circulation heat exchangers

Immersion coolers LAUDA ETK - Temperature range -50...20 °C

LAUDA immersion coolers provide a quick way to extend the temperature range downwards when used in conjunction with heating thermostats, water baths and cooling traps. The thermostats work on the classical principle of direct evaporation, and the flexible hose connection means that they can be used without any problems. The ETK 50 even has adjustable temperature control.

Advantages

- Compact space-saving construction
- Carrying handles for easy transport
- Cooling coil made from high-grade stainless steel
- Flexible tube connection with special insulation (length 1.5 m)

Anwendung1

Through-flow coolers LAUDA DLK - Temperature range -40...150 °C

LAUDA through-flow coolers upgrade any type of heating thermostat with pump connections to a high-quality cooling thermostat and thus allow working below ambient temperature. Through-flow coolers replace cooling with tap water that is expensive and ecologically not recommandable. They provide a constant flow and temperature of cooling supply regardless of the variations. Therefore, it is possible to ensure optimum temperature stability over the entire period and allow reproducible temperature conditions at any time.

Advantages

- Air-cooled, fully hermetic and thus absolutely
  maintenance-free cooling aggregates with heat
  exchangers in reasonable dimensions.
- Heat exchangers are made from stainless steel.
- All refrigerated parts inside the through-flow
  cooler are perfectly insulated. Therefore no
  condensation of water or risk of corrosion.
- Low-noise emissions

Anwendung1

Circulation heat exchangers LAUDA UWT - Temperature range 8...25 °C

Regulated circulation heat
exchangers – also known as system separators – guarantee temperatures, pressures and volume flow rates adapt to the application. The LAUDA UWT take cooling water from an existing circulation system in the laboratory and thermostat an internal bath volume in an individually-adjustable manner: this bath volume is then transported to the application via a pump in the
laboratory circulation system.

Advantages

- High pump capacity for good heat exchange
- High temperature stability even when there are
  temperature fluctuations in the primary circuit
- Compact design for easy installation
- High degree of process safety thanks to adapted
  cooling capacity
- Free of refrigerants

Advantages Advantages2
Enlargement - click here

LINKS AND REFERENCES